The main output on the unit has four taps, allowing the selection of output voltages up to 240V and output currents up to 200A.
Current
Output @230V
Range
Continuous
5 min*
1 min*
6 sec**
O/CV
Load V
10V
33A
67A
100A
200A
10.6V
8.7V@100A
35V
10A
20A
30A
-
36V
32V@30A
100V
3A
6A
10A
-
108V
99V@10A
240V
1A
2A
3A
-
276V
259V@3A
240Vdc
1A
2A
3A
-
*Off time of 15 minutes. On times based on an ambient temperature of 25°C.
**6 second intermittent ratings available with 230V supply.
Protection: over current trip, duty cycle trip, thermal monitoring.
I Limit Mode
The main output has a current limit mode that gives very fine control of output currents up to 10A. It also allows fine current control into very low impedance loads such as digital relays.
Current
Output @230V
Range
Short Circuit
Continuous
5min
2min
O/CV
Load V
10V
10A
3A
6A
10A
8.6V
5V@6A
35V
3A
1A
2A
3A
29V
132V@30A
100V
1A
0.3A
0.6A
1A
88V
99V@10A
240V
0.3A
0.1A
0.2A
0.3A
224V
259V@3A
Auxiliary DC Output
Range
Maximum A
Continuous Rating
12-60V
1A
25W
60-220V
0.23A
25W
Protection: current limit
Phase-shifting AC Output
Maximum Output Voltage
Current
Current
Range
No Load
Full load
Continuous
5 min on/15 min off
0-130V
144V
125V
0.23A
0.46A
0-260V
288V
250V
0.11A
0.23A
0-6V
6.6V
5V
5A
10A
Frequency range: 45—100Hz
Phase angle: 0—±180°
Protection: current limit & electronic trip.
Metering
The output is metered by a digital true RMS system with a single cycle capture memory ammeter—whenever the timer stops and the output is switched off, the current reading is held on the display. The RMS value of a single cycle can be captured. A current trip is set to 110% of full scale of the selected metering range.
Range
Resolution
Trip
current
Accuracy
Aquisition
time
5.000A
0.001A
5.5A
±0.5% rdg±5d
20ms
20.00A
0.01A
22A
±0.5% rdg±5d
20ms
50.00A
0.01A
55A
±0.5% rdg±5d
20ms
200.0A
200.0A
220A
±0.5% rdg±5d
20ms
Auxiliary Metering Inputs
Setting
Range
Resolution
Accuracy
Vdc/ac rms
300.0V
0.1V
±0.7% rdg±5d
Idc/ac rms
5.000A CF<3
9.999A CF<1.5
0.001A
±0.7% rdg±5d
Phase
-179.9° to +180.0°
0.1°
±3°
Frequency
40-100Hz
0.01Hz
±0.02% rdg±2d
Protection: fuse on current input
Timing System
Range
0-999.999s/9999.99s/99999.9s autoranging
Resolution
1/10/100ms
Accuracy
0.01%rdg+2d (+4d current operated mode)
Contact o/c
24V
Contact s/c
20mA
Vdc
24—240V
Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24—240Vdc may also be used to trigger either timer channel. Contact state is shown by an LED.
An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010 and is CE marked.
Temperature Range
Storage -20°C to 60°C
Operating0°C to 45°C
Standard Accessories
The 200ADM-P is supplied with operating manual, mains lead and,output lead set and spare fuses.
Optional Accessories
USB keyboard, 2Gb USB memory key, 100ADM-F filter unit, RB10 resistor box, printer kit.