left margin
  » Products  » Current Injection
200ADM-P Specification

Main Output

The main output on the unit has four taps, allowing the selection of output voltages up to 240V and output currents up to 200A.

Current

Output @230V

Range

Continuous

5 min*

1 min*

6 sec**

O/CV

Load V

10V

33A

67A

100A

200A

10.6V

8.7V@100A

35V

10A

20A

30A

-

36V

32V@30A

100V

3A

6A

10A

-

108V

99V@10A

240V

1A

2A

3A

-

276V

259V@3A

240Vdc

1A

2A

3A

-

*Off time of 15 minutes. On times based on an ambient temperature of 25°C.
**6 second intermittent ratings available with 230V supply.

Protection: over current trip, duty cycle trip, thermal monitoring.

I Limit Mode

The main output has a current limit mode that gives very fine control of output currents up to 10A. It also allows fine current control into very low impedance loads such as digital relays.

Current

Output @230V

Range

Short Circuit

Continuous

5min

2min

O/CV

Load V

10V

10A

3A

6A

10A

8.6V

5V@6A

35V

3A

1A

2A

3A

29V

132V@30A

100V

1A

0.3A

0.6A

1A

88V

99V@10A

240V

0.3A

0.1A

0.2A

0.3A

224V

259V@3A

Auxiliary DC Output

Range

Maximum A

Continuous Rating

12-60V

1A

25W

60-220V

0.23A

25W

Protection: current limit

Phase-shifting AC Output

Maximum Output Voltage

Current

Current

Range

No Load

Full load

Continuous

5 min on/15 min off

0-130V

144V

125V

0.23A

0.46A

0-260V

288V

250V

0.11A

0.23A

0-6V

6.6V

5V

5A

10A

Frequency range: 45—100Hz
Phase angle: 0—±180°
Protection: current limit & electronic trip.

Metering

The output is metered by a digital true RMS system with a single cycle capture memory ammeter—whenever the timer stops and the output is switched off, the current reading is held on the display. The RMS value of a single cycle can be captured. A current trip is set to 110% of full scale of the selected metering range.

Range

Resolution

Trip
current

Accuracy

Aquisition
time

5.000A

0.001A

5.5A

±0.5% rdg±5d

20ms

20.00A

0.01A

22A

±0.5% rdg±5d

20ms

50.00A

0.01A

55A

±0.5% rdg±5d

20ms

200.0A

200.0A

220A

±0.5% rdg±5d

20ms

Auxiliary Metering Inputs

Setting

Range

Resolution

Accuracy

Vdc/ac rms

300.0V

0.1V

±0.7% rdg±5d

Idc/ac rms

5.000A CF<3
9.999A CF<1.5

0.001A

±0.7% rdg±5d

Phase

-179.9° to +180.0°

0.1°

±3°

Frequency

40-100Hz

0.01Hz

±0.02% rdg±2d

Protection: fuse on current input

Timing System

Range 0-999.999s/9999.99s/99999.9s autoranging
Resolution 1/10/100ms
Accuracy 0.01%rdg+2d (+4d current operated mode)
Contact o/c 24V
Contact s/c 20mA
Vdc 24—240V


Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24—240Vdc may also be used to trigger either timer channel. Contact state is shown by an LED.

Supply Requirements

115V/230V ±10% auto-selecting 50/60Hz 1ph 2300VA max.

Safety

An earth terminal is provided for connection to a local earth. The unit is designed to comply with BSEN61010 and is CE marked.

Temperature Range

Storage -20°C to 60°C
Operating0°C to 45°C

Standard Accessories

The 200ADM-P is supplied with operating manual, mains lead and,output lead set and spare fuses.

Optional Accessories

USB keyboard, 2Gb USB memory key, 100ADM-F filter unit, RB10 resistor box, printer kit.

The unit is supplied as standard in an aluminium case with removable lid. The unit is also available in a plastic Pelicase as an option. Please note that the Pelicase lid is not removable andopens as far as shown in the picture below.

Weights and Dimensions

Dimensions Weight
Standard unit 380mm x 314mm x 221mm 19.5kg
Pelicase unit 560mm x 456mm x 265mm 23.3kg

200ADM-P in standard aluminium case

Pelicase option

Pelicase option













  Other Pages
  • Current Injection
  • 200ADM Current Injection System
  • 100ADM mk4 Current Injection System
  • 100ADM-F Current Filter Unit
  • 100A/E Current Injection system
  • CIT Primary Current Injection System
  • PCU1 Primary Current Injection System
  • PCU2 Primary Current Injection System
  • 50A-3PH Three Phase Current Injection System
  • 200A-3PH/ED Three Phase Current Injection System
  • 750ADM mk2 Current Injection System
  • 750ADM-AL Lead Set
  • 200ADM-P Current Injection System
  • 200ADM-P Specification
  • 100/200ADM-AL Lead set
  • RB10 Resistor Box


    Sub Categories

    right margin
    bottom margin
       
    T&R Test Equipment | Tel. +44 (0)1483 207428