left margin
  » Products  » Current Injection
CIT Primary Current Injection System

Features

  • 6.9kVA output capability
  • Continuously variable output
  • Multi-function digital timing system
  • Digital true RMS ammeter with memory
  • Bright LED displays
  • Automatic switch-off at end of test
  • Rugged, compact design
  • Loading units from 500A-3000A
  • Low impedance, dual-range outputs

CIT PCU1E Data sheet (high quality)

397kb

CIT PCU1E Data sheet

76kb

The CIT primary current injection systemis ideally suited to commissioning and maintenance testing where high currents up to 3000A are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The unitis capable of injection of currents up to 3000A with an LU3000LP loading unit.

The combination of theCIT and a suitable loading unit is ideal for many low power primary current injection tasks up to 3000A, andis one of a pairof productswith differing facilities.

Feature CIT PCU1/E
Primary injection ü ü
Timer ü ü
Secondary injection û ü

Where higher power is required, the PCU2/E and associated loading units can inject currents up to 6000A at 20kVA.

Four loading units are available, delivering output currents between 250A and 3000A. The LU3000LP 3000A loading unit is illustrated. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the LU3000LP may be configured to either give a maximum current of 1500A at 4V or 3000A at 2V.

A full range of output leads are available to complement theCIT and loading units.

The control units are rated at 6.9kVA, and have digital current metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips.

The CIT has a flexible timing system , allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, and many current trips and circuit breakers.

LU3000LP, LU500 and PCU1/E:









 
CIT Control Unit Specification 


  Other Pages
  • Current Injection
  • 200ADM Current Injection System
  • 100ADM mk4 Current Injection System
  • 100ADM-F Current Filter Unit
  • 100A/E Current Injection system
  • CIT Primary Current Injection System
  • PCU1 Primary Current Injection System
  • PCU2 Primary Current Injection System
  • 50A-3PH Three Phase Current Injection System
  • 200A-3PH/ED Three Phase Current Injection System
  • 750ADM mk2 Current Injection System
  • 750ADM-AL Lead Set
  • 200ADM-P Current Injection System
  • 200ADM-P Specification
  • 100/200ADM-AL Lead set
  • RB10 Resistor Box


    Sub Categories

    right margin
    bottom margin
       
    T&R Test Equipment | Tel. +44 (0)1483 207428
    info@trtest.com | Top | Site map