The PCU2/E Mk4 primary current injection system is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables.
The control unit may be used with one of a range of loading units providing between 3000A and 6000A of output current. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the LU6000 may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V.
The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the availables current.
The PCU2/E Mk4 control unit is shown here with an LU6000 loading unit. This combination may be used to inject currents of up to 6000A.
This unit is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing.
The control unit is rated at 20kVA, and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips.
A flexible timing system is provided, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and overcurrent devices, reclosers, under and over voltage devices, current trips and circuit breakers.