left margin
  » Products  » Current Injection
50A-3PH Three Phase Current Injection System

Features

  • Clear and simple user interface
  • 3 phase current output
  • 0-50A per phase output current
  • True RMS digital metering
  • Memory ammeter
  • Multi-function timing system
  • Auxiliary metering input
  • Large back-lit liquid crystal display
  • Thermal and over-current protection
  • Compact and portable
  • 220V or 400V3 phase mainssupply options
  • 115V-440V 3 wire supply with
    optional supply transformer
  • Optional ADMlog data capture software

50A-3PH Data sheet rev 6

262.79kb

ADMlog v1 Data sheet rev 1

277.09kb

The 50A-3PH is a three phase injection system providing commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate.

The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 50A. Voltages up to 18V are available on the main outputs. Three true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety.

The 50A-3PH is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. Auxiliary outputs and inputs are fuse protected.

The back-lit display on the 50A-3PH is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display



An auxiliary metering input is provided and can measure voltage, current, frequency, and the phase between any of the current outputs and an external voltage or current.

The timing system is very flexible without compromising ease of use, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. Two independently isolated contact inputs are provided, and the timing system may also be used as a stand-alone timer.

The 50A-3ph can be used to test many types of single and three phase secondary protection including:

  • Over and under current relays
  • IDMT relays
  • Auto-reclosers
  • Time delay relays
  • Earth fault relays
  • Miniature circuit breakers
  • Power relays
  • Tripping relays
  • Thermal relays

When used in conjunction with a DVS3 3 phase voltage source the 50A-3PH may be used to test most types of protection requiring three voltages and three currents including:

  • Directional overcurrent relays
  • Distance protection relays
  • Phase angle relays
  • Power transducers
  • Power relays

Further details and application information may be found on the 50A-3PH and DVS3 mk2 combined data sheet:

50A-3PH DVS3 mk2 Combined data sheet (high quality)

1.4Mb

50A-3PH DVS3 mk2 Combined Data Sheet

668kb









 
50A-3PH Specification 


  Other Pages
  • Current Injection
  • 200ADM Current Injection System
  • 100ADM mk4 Current Injection System
  • 100ADM-F Current Filter Unit
  • 100A/E Current Injection system
  • CIT Primary Current Injection System
  • PCU1 Primary Current Injection System
  • PCU2 Primary Current Injection System
  • 50A-3PH Three Phase Current Injection System
  • 200A-3PH/ED Three Phase Current Injection System
  • 750ADM mk2 Current Injection System
  • 750ADM-AL Lead Set
  • 200ADM-P Current Injection System
  • 200ADM-P Specification
  • 100/200ADM-AL Lead set
  • RB10 Resistor Box


    Sub Categories

    right margin
    bottom margin
       
    T&R Test Equipment | Tel. +44 (0)1483 207428